PCS6000—Medium Voltage Wind Turbine Converter Service Tools VLM70 3BHE034262R0001

admin

Byadmin

Sep 12, 2025

  Converter service tools

  It is recommended to have the converter service tools (according to Table 3–2) available on each converter site.

  Converter service toolbox

  Figure 3–1 Converter service toolbox

  – Weight: 4 kg

  – Length: 600 mm

  – Width: 400 mm

  – Height: 111 mm

  The converter service toolbox contains the tools listed in Table . These tools are required for replacing components in the POU (IGCTs, diodes, capacitors and resistors).

  Table 3–4 Converter service toolbox content (3BHB008753R0002)

  Designation Order number

  hex-key, 5 mm NB 307950P0513

  hex-key, 3 mm NB 307950P0511

  6HEX PIN INSERT 1/2” 12 mm WMN 400007P0212

  Double fork key C 21×23 WM 420039P0023

  Extension 1/2”-130 GMN 744036P0028

  RATCHET 1/2Z GMN 744036P0043

  Spreader tool 3BHE041414R0001

  Table 3–4 Converter service toolbox content (3BHB008753R0002) (continued)

  Designation Order number

  Spreader jaw 1 3BHE041418R0001

  Spreader jaw 2 3BHE041429R0001

  Main pipe 3BHE041430R0001

  Secondary pipe 3BHE041431R0001

  Hex socked set screw M24x50 3BHL001192P0001

  SCR-CYL-ISO4762-AM10X40-A2-70 NB 315840P0259

  SSW-ISO4026-M8X25-A2-21H GMN 323232P6211

  Double fork key C 12X13 WM 420039P0005

  DG-key C18x20 3BHE009970R0001

  6HEX PIN INSERT 1/2” 8 mm WMN 400007P1208

  View briefcase A4 Q 101130P0021

  Assembling jig HEFA415052

  FADEC 3 – Semiconductor inspection tool 3BHE043725R0001

  Hexagon key 8 (32×112) with ball head 3BHE055664R0002

  Hexagon key 4 (22×80) with ball head 3BHE055664R0001

  Screwdriver P-B 135 5 3BHE055712R0001

  The spreading tool (see Fig. 3–2) is used to release the stacks containing semiconductors to allow replacement of semiconductors. See also section 10.6.3, Using the spreading tool, page 145.

  The stabilizer plate (see Fig. 3–3) is used to stabilize the stacks containing semiconductors during replacement. See section 10.7.2, Releasing the stacks, page 179.

  Figure 3–3 Stabilizer plate (part of converter service toolbox) The FADEC 3 is a test device to find defective semiconductor in the stack. See chapter 9, Checking diodes, IGCTs and IPS, page 115 and the “PCS6000 user manual”, 3BHS600000 E40.

  Grounding kit

  Figure 3–5 Grounding kit

  – Weight: 15 kg

  – Length: 1000 mm

  – Width: 300 mm

  – Height: 300 mm

  The grounding kit comprises the grounding device with four ground connectors (made of 95 mm2 stranded copper wire with three 1 m long ends for phase connection and a 2 m long end for PE connection), a connection pole and a bag.

  The grounding kit is used to ground the converter before any service or maintenance work on the converter is done.

  Tube cutter

  Figure 3–6 Tube cutter

  – Weight: approximately 200 g

  – Length: approximately 100 mm

  – Width: approximately 100 mm

  – Height: approximately 20 mm

  The tube cutter is used to adjust the length of the water cooling tubes in the converter. The tool can cut tube diameters between 2 and 12 mm.

  Instruction to connect tubes to Legris adapters

  1. Cut the tube plane with the cutter. If the tube was already assembled, cut off the groove that was caused by the lock washer.

  2. Insert the tube into the Legris adapter as far as it will go.

  3. Make sure that there is no mechanical stress on the tube, especially not from sideways.

  3.2.4. Polishing kit for fiber optics

  Figure 3–7 Polishing kit for fiber optics (used with all connection types)

  The polishing kit for fiber optics is used to prepare and polish plastic fiber optical cables from Avago. These fiber optic cables are used in the converter for the control system.

  Commissioning tools

  The commissioning tools (according to Table 3–2) are intended for com-missioning of the PCS6000, but they are also used for service tasks.

  RCI-Box XU D194

  Figure 3–8 RCI-Box XU D194 with power cables and fiber optic cables

  – Weight: approximately 2 kg

  – Length: 275 mm

  – Width: 136 mm

  – Height: 101 mm

  – Input: 24V DC

  The RCI-Box (Remote Control Interface) XU D194 is used to transfer digital measurement signals from the main controller to an oscilloscope. This allows to monitor internal measurement signals in real-time without having to install any probes in the converter.

  The digital internal signals are converted to analog signals and sent to the oscilloscope by the RCI-Box. The signals to be monitored can be freely selected in the PCS6000 HMI. A maximum of 8 channels can be monitored simultaneously with one RCI.Box.

  PCS6000 HMI

  The PCS6000 HMI is used for monitoring/controlling of the converter during commissioning and service. It will be installed locally on the IPC (Industrial PC) in the converter. Access is obtained remotely using the remote desktop protocol.

  – Functionality of the PCS6000 HMI:

  – Single line diagrams of converter status

  – Main operational status values

  – Alarm / fault viewer

  – View / operate inputs and outputs signals

  – Overview and control of converter state

  – Usage of RCI-Box

  – Online measurement data monitoring (option)

  User interface (main screen) of the PCS6000 HMI:

  Filling kit for PCS6000 water cooling

  Figure 3–10 Filling kit for PCS6000 water cooling

  – Weight: approximately 10 kg

  – Length: 400 mm

  – Width: 300 mm

  – Height: 300 mm

  – Power: 850 W

  – Input: 1x 220 – 240 V AC 50Hz

  The filling kit for PCS6000 water cooling is used to fill the water cooling system with cooling

  liquid. It consists of a pump with one hose to connect to the converter (with connection) and one to the water source.

  The standard length of the tube between pump and converter is 2 meters.

  The use of the filling kit for PCS6000 water cooling is described in the Operation and maintenance manual of the PCS6000 water cooling system (provided in Appendix A06,

  Data sheets components of the user manual).

  Filling kit extension tube

  Figure 3–11 Filling kit extension tube

  – Weight: 0.25 kg/m

  – Outer diameter: 22 mm

  If the tube of the filling kit for PCS6000 water cooling is not sufficient, ie, if the distance between the converter and the water source is bigger than 2 meters, an extension tube is available.

  The length of the extension tube can be selected (maximum 25 meters).

  Replacement tools

  The replacement tools (according to Table 3-3) are required very seldom and therefore it is suggested to bring them on site only when required.

  Reactor replacement kit

  Figure 3–12 Reactor replacement kit

  – Weight: approximately 6 kg

  – Length: 700 mm

  – Width: 570 mm

  – Height: 206.5 mm

  The reactor replacement kit can be installed at the lower beam of the cabinet to pull out the filter reactor on its slides. Two M10 ring bolts (not shown in Fig. 3–12) are also part of the reactor replacement kit.

  The use of the reactor replacement kit is shown in Fig. 10–99.

  Base beam lifting jack

  Figure 3–13 Base beam lifting jack (3BHE039648R0001)

  – Weight: approximately 1 kg

  – Length: 100 mm

  – Width: 75 mm

  – Height: 125 mm

  The base beam lifting jack can be hooked into the top frame of the converter cabinet, eg, to hang up a chain-block. The structure of the converter can carry a maximum 250 kg load on the lifting jack in any top frame mounting position.

  The use of the base beam lifting jack is shown in Fig. 10–80 “Use of chain-block to lift out pump” on page 231.

  Chain-block

  Figure 3–14 Chain-block

  – Weight: 2.4 kg

  – Length: 84 mm

  – Width: 88 mm

  – Height: 217 mm

  The chain-block is used to remove heavy parts as transformers, reactors or pumps from the cabinet. It has to be used together with a base beam lifting jack (see section 3.4.2, Base beam lifting jack, page 42).
Related product recommendations:
3BHE034262R0001 ABB
3BHE046085R0100 DLU75
3BHE046085R0100 ABB
3BHE057853R0001 PCM02B
3BHE057853R0001 ABB
3BHE046081R0100 DLU74
3BHE046081R0100 ABB
3BHE046084R0001 VFM74
3BHE046084R0001 ABB
3BHE031197R0001 PCD I01-01
3BHE031197R0001 ABB
3BHE051397R0101 POM72
3BHE051397R0101 ABB
3BHE051398R0102 POU72
3BHE051398R0102 ABB
3BHE034444R0001 DAM10
3BHE034444R0001 ABB
3BHE057277R0001 ABB
3BHE057277R0001 CCA2 FR-Q-HX-U
3BHE032593R0002 IPS 21-24V-ULL
3BSE003390R1 SA167
3BSE003390R1 ABB
CCA1 FR-Q-HX-UL ABB
3BHE051396R0001 ASM12
3BHE051396R0001 ABB
3BHE031197R0001 PCDI0-01
3BHE031197R0001 ABB
3BHE056532R0001 CCU14
3BHE056532R0001 ABB
3BHE055094R0004 GBU72
3BHE055094R0004 ABB
3BHE055094R0003 GBU72
3BHE055094R0003 ABB
3BHE055094R0002 GBU72
3BHE055094R0002 ABB
3BHE055094R0001 GBU72
3BHE055094R0001 ABB
3BHE057277R0001 ABB
3BHE057276R0001 CCA1 FR-Q-HX-UL
More……

Leave a Reply

Your email address will not be published. Required fields are marked *