RED670 is used for the protection, control and monitoring of overhead lines and cables in all types of networks. The IED can be used from distribution up to the highest voltage levels. It is suitable for the protection of heavily loaded lines and multi-terminal lines where the requirement for tripping is one-, two-, and/or three-phase. The IED is also suitable for protection of cable feeders to generator block transformers.
The phase segregated current differential protection provides an excellent sensitivity for high resistive faults and gives a secure phase selection. The availability of six stabilized current inputs per phase allows use on multi-breaker arrangements in three terminal applications or up to five terminal applications with single breaker arrangements. The communication between the IEDs involved in the differential scheme is based on the IEEE C37.94 standard and can be duplicated for important installations when required for redundancy reasons. Charging current compensation allows high sensitivity also on long overhead lines and cables. A full scheme distance protection is included to provide independent protection in parallel with the differential scheme in case of a communication channel failure for the differential scheme. The distance protection then provide protection for the entire line including the remote end back up capability either in case of a communications failure or via use of an independent communication channel to provide a fully redundant scheme of protection (that is a second main protection scheme). Eight channels for intertrip and other binary signals are available in the communication between the IEDs.
A high impedance differential protection can be used to protect T-feeders or line reactors.
The auto-reclose for single-, two- and/or three phase reclosing includes priority circuits for multi-breaker arrangements. It co-operates with the synchronism check function with high-speed or delayed reclosing.
High set instantaneous phase and earth overcurrent, four step directional or un-directional delayed phase and earth overcurrent, thermal overload and two step under- and overvoltage functions are examples of the available functions allowing the user to fulfill any application requirement.
The IED can also be provided with a full control and interlocking functionality including co-operation with the synchronism check function to allow integration of the main or back-up control.
Disturbance recording and fault locator are available to allow independent post-fault analysis after primary disturbances.
The Disturbance recorder will also show remote station currents, as received to this IED, time compensated with measure communication time.
Out of Step function is available to separate power system sections close to electrical centre at occurring out of step.
The advanced logic capability, where the user logic is prepared with a graphical tool, allows special applications such as automatic opening of disconnectors in multi-breaker arrangements, closing of breaker rings, load transfer logics etc. The graphical configuration tool ensures simple and fast testing and commissioning.
A loop testing function allows complete testing including remote end IED when local IED is set in test mode.
Serial data communication is via optical connections to ensure immunity against disturbances.
The wide application flexibility makes this product an excellent choice for both new installations and the refurbishment of existing installations.
Four packages have been defined for following applications:
• Single-breaker (double or single bus) with three phase tripping (A31)
• Single-breaker (double or single bus) with single phase tripping (A32)
• Multi-breaker (one-and a half or ring) with three phase tripping (B31)
• Multi-breaker (one-and a half or ring) with single phase tripping (B32)
Optional functions are not configured but a maximum configuration with all optional functions are available as template in the graphical configuration tool. Analog inputs and binary input/output signals are pre-defined for basic use. Other signals may be required by each particular application.
Add binary I/O boards as required for the application when ordering.
For details on included basic functions refer to section
The applications are shown in figures 1 and 2 for single resp. multi-breaker arrangement.
The application on a high ohmic earthed system is shown in figure 1.
Refer to the Application manual for pre-configured analog and binary IO.