RS-FS-9001 362A1052P404 362A1052P001 Other Names:
Flame Tracker RS-FS-9001 362A1052P404 362A1052P001
RS-FS-9001 362A1052P404 362A1052P001 Ultraviolet Flame Sensor
Ultraviolet Flame Detector RS-FS-9001 362A1052P404 362A1052P001
Product Overview
The GE Reuter-Stokes RS-FS-9001 362A1052P404 362A1052P001 is an ultraviolet/infrared (UV/IR) flame tracking sensor designed specifically for high-temperature industrial environments. It utilizes silicon carbide (SiC) photodiode technology and features high sensitivity, fast response (<25ms), and a wide dynamic range. Its core function is to monitor the flame status in real-time in scenarios such as gas turbines, boilers, and petrochemical plants, ensuring safe equipment operation and preventing fire accidents. This model is widely used in high-risk environments such as gas turbines, boilers, petrochemical plants, and industrial kilns, and is a core component for flame monitoring in gas turbine combustion chambers.
Core Technical Parameters:
Detection Principle: Utilizes silicon carbide (SiC) photodiode technology, exhibiting high sensitivity to ultraviolet (UV) light, enabling rapid identification of flame signals from fuel oil and other sources. Response time is <25ms, ensuring timely and safe response.
Materials and Structure: Silicon carbide (SiC) sensor material, metal housing (gray, approximately 100mm × 100mm × 50mm, weight 1kg), protection rating IP54/IP65.
Electrical Parameters: Operating voltage 220V/24V DC or 115/230V AC, power consumption ≤5W, signal output 4-20mA analog or digital, compatible with GE control systems.
Environmental Adaptability: Operating temperature -10℃~70℃ (some models -20℃~60℃), storage temperature -20℃~85℃. High temperature resistant and vibration resistant, suitable for complex operating conditions such as steam injection and low NOx burners.
Response Characteristics: Sensitive to ultraviolet wavelengths (strong long-wavelength penetration), response time <25ms, supports detection of multiple fuel types (gas, oil, etc.).
Application Areas:
Core Scenarios: Flame monitoring in gas turbine combustion chambers, boiler combustion control, safety monitoring of petrochemical plants, fire prevention in the power/paper/tobacco industries.
Special Scenarios: High temperature, high humidity, steam injection environments, such as low NOx burners, industrial kilns, diesel generator sets, etc.
Safety Certifications: ETL, ATEX, IECEx certified, compliant with NFPA industrial safety standards, suitable for explosive hazardous areas.
Installation and Maintenance Guidelines
Installation Requirements: Use flange or threaded mounting. Ensure the detector is aligned with the flame combustion area, avoiding direct exposure to high-temperature flue gas. Use shielded cables for the signal line and keep away from sources of strong electrical interference.
Maintenance Recommendations: Clean the detector window regularly (calibrate every 6-12 months). Use specialized cleaning tools to avoid scratching the lens. If flame recognition anomalies occur, check the wiring connections, probe sensitivity, and impedance matching potentiometer.
Troubleshooting:
False Alarms/Missing Alarms: Clean the quartz lens if the probe lens is contaminated. If the impedance matching potentiometer is over-adjusted, slowly adjust it clockwise until the indicator light illuminates.
Line Interference: Humid environments may increase distributed capacitance; adjust the potentiometer in reverse until the relay releases.
Advantages and Alternatives
High Reliability: Industrial-grade high-temperature resistant materials and optimized optical components extend service life; quick-disconnect connectors reduce maintenance time.
Compatibility: As a standard replacement for GE’s combustion management system, it is fully compatible with original equipment manufacturer (OEM) specifications and supports upgrades of older sensors for land-based/marine gas turbines.
Extended Functions: Supports digital/analog signal output, seamlessly integrates with DCS, PLC, SCADA, and other systems for remote monitoring and data acquisition.
Performance Advantages:
High Sensitivity and Interference Resistance: SiC material is sensitive to long-wave UV light and has strong penetration capabilities through fuel/vapor mist, suppressing false alarms caused by welding arc light and sunlight.
Low Maintenance Costs: Low-voltage operation reduces special wiring requirements, and the quick-change design shortens maintenance time (from hours to minutes).
Interference Resistance Design: Effectively suppresses false alarms from welding arc light, sunlight, and lighting sources, adapting to complex environments such as high temperatures, vibration, and dust.
Self-Diagnostic Functions: Features optical channel contamination monitoring, window scaling detection, and system self-test functions, providing real-time feedback on abnormal states.
Quick Maintenance: Modular design supports quick replacement (replacement time reduced to minutes), equipped with quick-disconnect connectors to reduce maintenance costs.
Compatibility and Upgrades: Replaceable with older sensor models (such as tubular sensors), supports customized conversion kits, and is compatible with GE and other brand control systems.
Reliability: Leveraging 60 years of radiation monitoring technology, it adapts to extreme operating conditions, ensuring the safe continuous operation of gas turbines.
Typical Applications
Gas Turbines: Real-time monitoring of ignition and combustion status ensures safe start-up/shutdown and prevents equipment damage caused by flameout.
Petrochemical Industry: Early fire warning in high-temperature reactors and storage tank areas reduces explosion risk.
Power Industry: Optimizes boiler combustion control, improving combustion efficiency and reducing pollutant emissions.
Flame Monitoring: Real-time monitoring of combustion status ensures gas turbine ignition confirmation, continuous combustion monitoring, and safe shutdown, preventing unburned fuel leakage or explosion risks.
Anti-interference Design: Built-in algorithms suppress false alarms from welding arc light, sunlight, and lighting; optical channel contamination monitoring automatically detects window scaling and reports anomalies.
Multi-Scenario Adaptability: Widely used in power plant boilers, gas turbines, petrochemical combustion equipment, industrial kilns, etc., with particularly excellent performance under complex conditions such as steam injection or low-NOx burners.
Certifications and Compliance: Certified by international safety standards such as ETL, ATEX, and IECEx, meeting standards for use in hazardous areas (explosive atmospheres).
Summary: The RS-FS-9001 362A1052P404 362A1052P001, with its high sensitivity, rapid response, anti-interference capabilities, and industrial-grade reliability, has become a benchmark product in the industrial flame monitoring field. It is widely used in key industries such as energy, chemical, and manufacturing, providing a solid guarantee for the safe operation of equipment.
All products on this website are special products, and market prices are constantly fluctuating.
Please refer to customer service for a quote, as the price is not accurate for new products.
Please confirm the model, product, price, and other detailed information with customer service before placing an order. This website is currently in use.
New products are available for sale; please contact customer service for further information.


-300x300.jpg)
-300x300.jpg)

Reviews
There are no reviews yet.